1) Memorize working condition

***Memorizing Working condition and Using the memorized working condition***

1) Memorize working condition

UPPERSPEED

LOWERMEMORY

1.Operator can memorize 9 working conditions.

2.Each time you press the button, buzzer is ringing.

3.find the condition number you are willing to memorize working condition by pressing MEMORY button.

4.When you finish setting upper/lower temperature and speed, you can press the memory button.

This working condition is memorized while buzzer is ringing with blinking.

*If you change the temperature or speed and the display shows blinking at the same time, memory number is blinking together, it means that working cocdition is not set. When you memorize working condition, you have to press MEMORY button.

5.When you memorize another working condition, you can do above 3 and 4 operation over.

2) Use the memorized working condition.

1.Operator can choose one of 9 memorized working conditions.

2.Press MEMORY the 2) Use the memorized working condition. or Manual background to select a working condition. The display will blink.

3.After the blinking stops, it is set the working condition you selected and shows the working condition on the display.