4. Technical Specifications

4. Technical Specifications

4.1. Power Supply Specifications

Power Supply Type

Input Range

 

Internal Fuse Rating

Max. Power

Min

Max

Consumptiona

HI (125/250 VDC)b

88 VDC

300 VDC

6.3A, 250V(T)c

84 Wd

HI (110/230 VAC)b

85 VAC

264 VAC

6.3A, 250V(T)c

84 Wd

aPower consumption varies based on configuration, i.e. the number and type of ports. Each 10/100Base-TX port consumes roughly 1W less than a fiber optic port.

bThe “HI” power supply is the same power supply for both AC and DC.

c(T) denotes time-delay fuse. Internal fuse is not user-replaceable.

dRating at 85°C ambient temperature at worst-case load.

Table 4.1. Power Supply Specifications

4.2. Critical Alarm Relay Specifications

Parameter

Value

(Resistive Load)

Max Switching Voltage

250

VAC, 125 VDC

 

 

Rated Switching Current

2A@250VAC, 2A@30VDC

 

 

 

Table 4.2. Critical Alarm Relay Specifications

4.3. Copper Ethernet Port Specifications

The RX5000 can be ordered with several different modules which contain 10/100Tx or 10/100/1000Tx Ethernet ports. All copper Ethernet ports have the following specifications:

Parameter

Specification

Notes

Speed

10/100 or 10/100/1000 Mbps

Auto-negotiating

 

 

 

Duplex

FDX / HDX

Auto-negotiating

 

 

 

Cable-Type

> Category 5

Shielded/Unshielded

 

 

 

Wiring Standard

TIA/EIA T568A/B

Auto-Crossover, Auto-Polarity

 

 

 

Max Distance

100 m

 

 

 

 

Connector

RJ45

 

 

 

 

Isolation

1.5kV

RMS 1-minute

 

 

 

Table 4.3. Copper Ethernet Port Specifications