RuggedCom RX5000 manual Operating Environment, Mechanical Specifications, Parameter Range Comments

Models: RX5000

1 35
Download 35 pages 63.66 Kb
Page 31
Image 31

4. Technical Specifications

4.5. Operating Environment

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85°C

Ambient Temperature as measured from a 30cm

radius surrounding the center of the enclosure.

 

 

 

 

 

Ambient Relative Humidity

5% to 95%

Non-condensing

 

 

 

Ambient Storage Temperature

-40 to 85°C

 

 

 

 

Table 4.6. Operating Environment

4.6. Mechanical Specifications

Parameter

Value

Comments

Dimensions

6.9 x 17.9 x 11.89 inches

(Height x Width x Depth)

(175.26 x 454.66 x 302.01 mm)

 

 

 

 

 

Weight

Variable

Weight dependent on module complement.

 

 

 

Ingress Protection

IP40

(1 mm objects)

 

 

 

Enclosure

Aluminum

 

 

 

 

Table 4.7. Mechanical Specifications

RuggedCom® RuggedBackbone™

31

RX5000 Installation Guide Rev106

Page 31
Image 31
RuggedCom RX5000 Operating Environment, Mechanical Specifications, Parameter Range Comments, Parameter Value Comments