5. EMI And Environmental Type Tests
5. EMI And Environmental Type Tests
| Test | Description | Test Levels | Severity | ||
| Levels | |||||
| 
 | 
 | 
 | 
 | ||
| IEC  | ESD | Enclosure Contact | +/- 8 kV | 4 | |
| 
 | 
 | 
 | |||
| Enclosure Air | +/- 15 kV | 4 | |||
| 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Radiated RFI | Enclosure Ports | 20 V/m | Notea | |
| 
 | 
 | Signal ports | +/- 4kV @ 2.5kHz | Notea | |
| IEC  | Burst (Fast Transient) | D.C. Power ports | +/- 4kV | 4 | |
| 
 | 
 | 
 | |||
| A.C. Power ports | +/- 4kV | 4 | |||
| 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Earth ground ports | +/- 4kV | 4 | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Signal ports | +/- 4kV  | 4 | |
| 
 | 
 | +/- 2kV  | |||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Surge | D.C. Power ports | +/- 2kV  | 3 | |
| +/- 1kV  | |||||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | A.C. Power ports | +/- 4kV  | 4 | |
| 
 | 
 | +/- 2kV  | |||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Signal ports | 10V | 3 | |
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Induced (Conducted) RFI | D.C Power ports | 10V | 3 | |
| 
 | 
 | 
 | |||
| A.C. Power ports | 10V | 3 | |||
| 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Earth ground ports | 10V | 3 | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | 
 | 40 A/m, continuous, | Notea | |
| IEC  | Magnetic Field | Enclosure Ports | 1000 A/m for 1 s | 
 | |
| 
 | 
 | 
 | 1000 A/m for 1 s | 5 | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | D.C. Power ports | 30% for 0.1s, 60% for | N/A | |
| IEC  | Voltage Dips & Interrupts | 0.1s, 100% for 0.05s | |||
| 
 | 
 | ||||
| 
 | 
 | A.C. Power ports | 30% for 1 period, 60% for 50 periods | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Voltage Dips & Interrupts | A.C. Power ports | 100% for 5 periods, | N/A | |
| 100% for 50 periods | |||||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Signal ports | 2.5kV common, 1kV | 3 | |
| 
 | 
 | diff. mode@1MHz | |||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Damped Oscillatory | D.C. Power ports | 2.5kV common, 1kV | 3 | |
| diff. mode@1MHz | |||||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | A.C. Power ports | 2.5kV common, 1kV | 3 | |
| 
 | 
 | diff. mode@1MHz | |||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Mains Frequency Voltage | Signal ports | 30V Continuous, 300V for 1s | 4 | |
| 
 | 
 | 
 | |||
| D.C. Power ports | 30V Continuous, 300V for 1s | 4 | |||
| 
 | 
 | ||||
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Ripple on D.C. | D.C. Power ports | 10% | 3 | |
| Power Supply | |||||
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Signal ports | 2kVAC  | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | Dielectric Strength | D.C. Power ports | 1.5kVDC | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | A.C. Power ports | 2kVAC | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | Signal ports | 5kV  | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| IEC  | H.V. Impulse | D.C. Power ports | 5kV | N/A | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | 
 | A.C. Power ports | 5kV | N/A | |
a
Table 5.1. IEC 
| RuggedCom® RuggedBackbone™ | 32 | RX5000 Installation Guide Rev106 | 