APX-6
Appendix 2
CENTERING THE CAMERA
The camera must be centered in middle of the projection
screen. Follow the steps described below:
Highlight CENTER CAMERA by pushing the up or
down keys of the control disc.
Press the <ENTER> button to start up the process.
Note: It is critical that the green raster of the presently select-
ed source is centered on the CRT faceplate. Other-
wise, the camera will not be centered properly.
CENTERING THE CAMERA HORIZONTALLY
One vertically centered green bar will be projected onto the
screen, together with a text box. Inside the box, the text of
“CAMERA ALIGNMENT HORIZONTAL” indicates the item
subject to adjustment and a symmetrical bar scale (from -50
to +50) under text.
If the indicated value below the bar scale is not equal to zero
(i.e. the black highlight is not in the middle of the bar scale),
the camera is not centered horizontally. Follow the steps
below to center the camera horizontally:
Turn the knob situated on the upper-right corner of the cam-
era clockwise or counter clockwise until the highlight is in the
middle of the bar scale (i.e. the indicated value becomes
zero);
Press the <ENTER> button to continue with the camera ver-
tical centering.
Note: An easy way to remember the H+V adjustments is:
The knob located up/down from the fixed screw is ver-
tical adjustment. The knob located left/right from the
fixed screw is horizontal adjustment.
EYE-Q
TOUCH UP
AUTOCONVERGENCE
QUICK AUTOPICTURE
FULL AUTOPICTURE
EYE-Q SETUP
EYE-Q DIAGNOSTICS
Select with
then <ENTER>.
<EXIT> to return
or
EYE-Q SETUP
FOCUS THE LENS
CENTER THE CAMERA
CONFIGURATION: rear/front
LEARN REFERENCE
TOUCH-UP OPTIONS:
Select with
then <ENTER>.
<EXIT> to return
or
+00
CAMERA
ALIGNMENT
HORIZONTAL
T
V
L
E
N
S
8
m
m
T
V
L
E
N
S
8
m
m
Fixed screw
No Adjustment
Knob for centering
the camera vertically Knob for centering
the camera
horizontally