Runco VX-44D, VX-55D manual 3. Removing the Lamp, 4. Installing A New Lamp

Models: VX-55D VX-44D

1 114
Download 114 pages 2.55 Kb
Page 92
Image 92
Figure 5-3. Removing the Lamp

Maintenance and Troubleshooting

4.Grasp the lamp by its housing only and pull it straight out (lamp slides along guides) until it’s free; see Figure 5-3.Discard the lamp using safe disposal/recycling practices or contact your Runco dealer for a possible re-lamping program.

Figure 5-3. Removing the Lamp

5.Align the new lamp with the top and bottom guides on the left side of the lamp compartment; see Figure 5-4.Slide the lamp all the way in. A slightly harder push may be required right at the end to make sure it is fully seated into the terminal block. NOTE: The projector will not power up again if the lamp is not fully connected to the terminal block.

Figure 5-4. Installing A New Lamp

6.Pull (out) and turn the lamp lock lever (turned up in Step 3) a quarter turn clockwise to “lock” the lamp in place.

If you can’t turn the lamp lock into position, the lamp may not be

Note fully inserted. In this case, partially remove the lamp and try pushing it back in again. Then, try switching the lock lever to the “lock” position.

7.Replace the lamp door and secure it with the screws.

8.Re-attach the power cord to the projector and power it up.

9.Press MENU on the projector remote control (Figure 3-16)or rear-panel keypad (Figure 2-3).

10.Select Lamp Adjust from the Main Menu.

11.Select Change Lamp from the Lamp menu.

12.Enter the serial number in the Lamp S/N text box using the remote numeric keypad.

80

Runco VX-44d/-55d Owner’s Operating Manual

Page 92
Image 92
Runco VX-44D, VX-55D manual 3. Removing the Lamp, 4. Installing A New Lamp