Trigger Connections
Home Theater Triggers
These triggers are used to integrate with home theater systems that can provide a 12 volt trigger. The
IN
This 12VDC Trigger input will have different functionality based on the state of the system and the state of the trigger. The connections for the trigger are made using a
"System Off’ (all zones have been off for at least 5 minutes): If 12VDC is applied to this input, it will activate the power management ON command to the sources. While all zones are still OFF and 12VDC is removed, the system will wait 5 minutes and then activate the power management OFF command to the sources.
"System On" (at least one zone is on): If 12VDC is present but all zones get turned OFF, the power management OFF commands will not be sent until 5 minutes after the 12VDC is removed from the trigger.
Note: If the trigger is not being used, power management will operate normally.
OUT
The 12VDC 100mA trigger out can be used to engage any 12VDC trigger device or component such as the Russound
The output will be activated when the first zone is turned on (system on) and is deactivated six minutes after the last zone is turned off (system off), unless the home trigger input has 12VDC present.
Tip - Pos (+)
3.5mm Plug
Sleeve - Neg
Polarity of 3.5mm Plug
24 | Russound |