ASSEMBLY

TO SQUARE THE SAW TABLE TO THE BLADE

See Figure 11.

nTurn the blade guide lock knob counterclockwise to unlock the blade guide assembly. Turning the blade guide knob clockwise, raise the blade guide assembly as far as it will go. Turn the lock knob clockwise to retighten.

nPlace a small combination square on the saw table beside the blade.

nLoosen the bevel lock knob and rotate the bevel adjustment knob to tilt the saw table up or down to align table 90° to blade (0° position). Retighten the bevel lock knob.

nUsing a hex key, adjust the zero stop set screw until the set screw just touches the saw housing.

nCheck squareness of the saw table to the blade. Make readjustments if necessary.

nLoosen screw on scale indicator with a phillips screwdriver and align scale indicator to zero.

nTighten all screws securely.

TO INSTALL DUST BAG

See Figure 12.

This tool comes with a dust bag for dustless cutting. To install the dust bag:

nPosition the nozzle of the dust bag in line with the dust exhaust port on the back of the band saw.

nPush the dust bag nozzle firmly into the exhaust port.

NOTE: For more efficient operation, empty dust bag when no more than half full. Turn bag inside-out and shake vigorously to remove dust. This will permit better air flow through the bag.

LOCK KNOB

TABLE

ALIGNING

BOLT

BLADE GUIDE KNOB

WASHER

WING

NUT

Fig. 10

ZERO STOP

BLADE

SET SCREW

GUARD

SMALL

COMBINATION

SQUARE

SAW

BLADE

Fig. 11

DUST

EXHAUST

PORT

DUST

BAG

Fig. 12