MAINTENANCE

SPOOL REPLACEMENT

(NEW PREWOUND SPOOL)

See Figures 14 - 15.

If replacing string only, refer to String Replacement later in this manual.

Use only monofilament string. For best performance, use original manufacturer’s replacement string.

String Diameter: .080 in. (2.0 mm)

Stop the engine and disconnect the spark plug wire. Hold the string head and unscrew the spool retainer.

Turn the spool retainer counterclockwise.

Remove the empty spool from the string head. Keep the spring attached to the spool.

To install the new spool, make sure the two strings are captured in the slots opposite each other on the new spool. Make sure the ends of each string are extended approximately 6 in. (152 mm) beyond each slot.

Thread the strings into the eyelets in the string head. Carefully push the spool into the string head (gently pull the strings to the outside if necessary). When the spool is positioned in the string head, grasp the strings and pull sharply to release them from the slots in the spool.

Push down and turn the spool counterclockwise until it no longer turns. Hold the spool down and rotate clockwise a small amount. Release the spool. The spool should be locked down in the string head. If not, hold down and rotate until locked.

Make sure the string head and the spool retainer are installed on the drive shaft.

Turn the spool retainer clockwise.

Pull the strings again to rotate the spool into cutting position. Push the spool retainer down while pulling on string(s) to manually advance the string and to check for proper assembly of the string head.

SPOOL

RETAINER

Fig. 14

SPRING

SLOTS

EYELETS

STRING HEAD

SHAFT

Fig. 15

15

Page 15
Image 15
Ryobi Outdoor RY30130, RY30120 NEW Prewound Spool, See Figures 14, Spool Retainer Spring Slots Eyelets String Head Shaft