Saab 9-3 M03 installation instructions 65Connect the negative battery cable

Models: 9-3 M03

1 16
Download 16 pages 29.61 Kb
Page 16
Image 16
12 788 928

16

12 788 928

 

 

 

 

62

62

61

64

 

62

 

 

 

 

63

 

 

 

 

69

 

 

 

63

F920A023

61Fit the heat shield to the turbo compressor (two screws and a catch).

62Fit the turbo intake pipe and then connect to the pipe the small hose from the control valve (APC valve) and the hose from the carbon filter vent valve.

63Fit the air filter cover and plug the connector into the air mass sensor. Attach the hose to the air fil- ter cover (if such a hose is fitted).

64Fill with coolant and check the system for leaks. Fit the expansion tank cap.

65Connect the negative battery cable.

66Connect the diagnostic tool, select car and mod- el year, select “All”, select “Add/Remove”, select the accessory and then “Add”.

67Bleed the cooling system in the following way:

Note

The A/C or ACC should be turned OFF.

Fill the coolant system to the MAX level. Close the expansion tank cap. Start the engine and run at varying engine speeds until the radiator fan cuts in. Carefully open the expansion tank cap and top up to the MAX level. Close the cap. Switch off the engine and if necessary top the coolant up to the MAX level.

68Start the heater by pushing the "CUSTOMIZE" button on the SIDC, select "Parking heater", push "SET", select "Manual control", push “SET”, select “Heater on”, push “SET” and check that the heater starts ( it has a delay of about 1 minute). If necessary top up the cooling system (engine switched off).

69Fit the cover over the bulkhead space, fit the bonnet seal and the wiper arms.

70Adjust the clock/date.

71Programme the heater Turn the ignition switch to the ON position, push the "CUSTOMIZE" but- ton on the SIDC, select "Parking heater", push "SET", select "Manual control" and check that the heater starts or select "Timer setting", "Tim- er”, select a timer; “A”, “B” or “C”, programme in a suitable time and push “SET”. Check that the heater starts at the programmed time.

Select “Manual control", press “SET”, select “Heater off”, press “SET” and check that the heater stops. Select “Back”, press “SET”, select “Finish” and press “SET”.