20 |
MODES OF OPERATION
MODES OF OPERATION
Dehumidification mode
or vice versa, it may be necessary to reposition the “humidity adjustment knob” in order to achieve the same degree of dehumidification.
•Plug the equipment into an appropriate outlet;
•Make sure that the “condensation collection tank full” LED is off.
Mirage - Mirage combi - Mirage plus
•Turn the “humidity adjustment” knob to the maximum
dehumidification position ( /);
•Press the
•The fan starts at the minimum speed; if the fan speed is to be increased, press the “air speed selection” push button once.
Note: the greater the speed of the fan, the greater the capacity of dehumidifying the air
When the room humidity has been lowered to the desired level, slowly turn the “dehumidification adjustment” knob counter clockwise until the compressor stops; in this way you will have adjusted the unit to automatically maintain the desired level of humidity.
Mirage S
•Turn the “humidity adjustment” knob to the maximum
dehumidification position (); by this way, the operation is simultaneously enabled.
Note: the fan and the compressor will start after a technical time set by the manufacturer; the “ON indication” LED will be on.
When the desired room humidity is reached, slowly turn the “dehumidification adjustment” knob counter clockwise until the compressor/fan stops and the led is off; in this way you will have adjusted the unit to automatically maintain the desired level of humidity.
Combi mode
(Mirage Combi only)
•Plug the equipment into an appropriate outlet;
•Make sure that the “condensation collection tank full” LED is off;
•Turn the “humidity adjustment” knob to the maximum
dehumidification position ( );
•Press the
•Press the “running mode” push button until the two LEDs that correspond to the “Combi” running mode are lit. The fan will run at maximum speed in this running mode;
•Press the “electronic thermostat” push button and select the desired temperature.
When the room humidity has been lowered to the desired level, slowly turn the “dehumidification adjustment” knob counter clockwise until the compressor stops; in this way you will have adjusted the unit to automatically maintain the desired level of humidity.
When the desired room temperature is reached, the electronic thermostat will automatically control the operation of the heating element to maintain the right temperature in the room.
If the running mode is changed from Dehumidification to Combi
Heating mode
(Mirage Combi only)
•Plug the equipment into an appropriate outlet;
•Make sure that the “condensation collection tank full” LED is off;
•Press the
•Press the “running mode” push button until only the “heating” LED remains lit; in this running mode the fan runs at maximum speed;
•Press the “electronic thermostat” push button and select the desired temperature.
When the desired room temperature is reached, the electronic thermostat will automatically control the operation of the heating element to maintain the right temperature in the room.
Condensation collection tank
The dehumidifier is automatically stopped when the condensation collection tank is full, regardless of the running mode in use; the corresponding LED on the control panel will light up when this occurs.
For the dehumidifier to begin running again you will need to empty the condensation collection tank as described below:
•open the filter holder grid by pulling the
•lift and remove the tank, using the extraction handle (Fig.B) situated at the bottom until the handle used for carrying the tank (Fig.C) can be easily reached.
The equipment is provided with an
•Empty the condensation collection tank;
•Check that the water has been drained also from the floater base (Fig.D);
•Put the condensation collection tank back into place, pushing it inwards.
If the degree of humidity of the air is greater than the degree of humidity selected (with the humidity adjustment knob), the dehumidifier will start automatically in the running mode previously selected.
Note: Do not force the door while attempting to remove the condensation collection tank; the equipment will not run without the tank in place.
Room Humidity Indication
(Mirage Plus only)
By plugging the unit into an outlet, the “humidity control” display will turn on and show the room humidity (also when the machine is off). The range displayed is between 30% and 80% .
Beyond these limits, the display could show a flashing message “LLL” (see the troubleshooting table).