Program 110 - PLU Auto Tare Programming

1.Turn the control lock to the P position.

2.To begin the program, enter 1 1 0, press the SBTL key

1 1 0 SBTL

3.Select the PLU or PLUs you wish to program in one of the following ways:

Press on the keyboard, or

PLU

Press the first PLU keys that are to receive the same status and Press the last PLU keys, or

PLU PLU

Enter up to 15 digit number of the PLU and press the PLU key, or

Enter the PLU#,

PLU

up to 15 digits

 

Enter the number of the first PLU in a range of PLUs that are to receive the same setting, and press the PLU key. Enter the last number in the range; press the PLU key.

Enter the PLU#,

PLU

Enter the PLU#,

PLU

up to 15 digits

up to 15 digits

 

 

4.Enter a value (1-5) to indicate the number of the preprogrammed tare weight you want to automatically subtract when the PLU is used for scale entry (using an optional scale). Enter 0 to disable automatic tare subtraction.

NX/TIME

5.Program additional PLUs, repeat from step 3, or press the CASH key to finalize the program

CASH

ER-380 / ER-380M

Program Mode Programming 89

Page 99
Image 99
Sam4s ER-380M specifications Program 110 PLU Auto Tare Programming