Samson S63, S83 manual Suggested Performance Application - S63

Models: S63, S83 S83

1 29
Download 29 pages 5.84 Kb
Page 23
Image 23
Suggested Performance Application - S63

Suggested Performance Application - S63

The following illustration shows the basic interconnections between an S63 and external equipment when used in a typi- cal live performance application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AMPLIFIER

 

 

 

 

 

 

 

 

 

 

CHANNEL 1

 

CHANNEL 2

 

CHANNEL 3

 

CHANNEL 4

 

CHANNEL 5

 

CHANNEL 6

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

−∞

+15

 

 

−∞

+15

 

 

−∞

+15

 

 

−∞

+15

 

 

−∞

+15

 

 

−∞

+15

 

 

−∞

+10

 

 

 

 

 

 

 

 

 

 

 

LEVEL

 

 

 

LEVEL

 

 

 

LEVEL

 

 

 

LEVEL

 

 

 

LEVEL

 

 

 

LEVEL

 

 

RETURN 1-2

 

 

S6 MIXER AMPLIFIER

 

 

 

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

−∞

+10

-15

+15

−∞

+10

-15

+15

−∞

+10

-15

+15

−∞

+10

-15

+15

−∞

+10

-15

+15

−∞

+10

-15

+15

−∞

+10

30Hz

64Hz

125Hz

250Hz

500Hz

1K

2K

3K

5K

10K

EFF1 MON

 

HIGH

EFF1 MON

 

HIGH

EFF1 MON

 

HIGH

EFF1 MON

 

HIGH

EFF1 MON

 

HIGH

EFF1 MON

 

HIGH

MONITOR

 

 

 

 

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

0

 

 

0

 

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

+15dB

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

−∞

+10

-12

+12

−∞

+10

-12

+12

−∞

+10

-12

+12

−∞

+10

-12

+12

−∞

+10

-12

+12

−∞

+10

-12

+12

0

10

 

 

 

 

 

 

 

 

 

0dB

EFF2 REV

 

1 kHz

EFF2REV

 

1 kHz

EFF2 REV

 

1 kHz

EFF2 REV

 

1 kHz

EFF2 REV

 

1 kHz

EFF2 REV

 

1 kHz

REVERB

 

 

 

 

 

 

 

 

 

 

 

10

 

0

 

10

 

0

 

10

 

0

 

10

 

0

 

10

 

0

 

10

 

0

 

 

 

 

 

 

 

 

 

 

 

-15dB

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

0

 

 

 

 

 

30Hz

64Hz

 

 

 

 

 

 

 

10K

+4

-40

-15

+15

+4

-40

-15

+15

+4

-40

-15

+15

+4

-40

-15

+15

+4

-40

-15

+15

+4

-40

-15

+15

 

 

125Hz

250Hz

500Hz

1K

2K

3K

5K

 

TRIM

 

LOW

 

TRIM

 

LOW

 

TRIM

 

LOW

 

TRIM

 

LOW

 

TRIM

 

LOW

 

TRIM

 

LOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

−∞

+10

 

 

 

 

 

 

 

 

CD/TAPE

 

LINE

 

 

 

LINE

 

 

 

LINE

 

 

 

LINE

 

 

 

LINE

 

 

 

LINE

 

 

MAIN LEVEL

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIC

 

 

 

MIC

 

 

 

MIC

 

 

 

MIC

 

 

 

MIC

 

 

 

MIC

 

PHANTOM

 

PEAK

PROTECTION

 

POWER

LEFT

RIGHT

 

 

 

 

 

 

 

 

 

MIDI TONE GENERATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

0

 

0

 

 

 

 

0

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL PROCESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

0

 

 

0

 

0

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EFFECT RETURNS

EFFECT SENDS

S6 MIXER AMPLIFIER

6 CHANNEL 210 WATT 4

SAMSON TECHNOLOGIES CORP., HICKSVILLE, NEW YORK

POWER

 

 

 

 

 

 

 

 

o

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO PREVENT SHOCK,

 

 

 

+4dB

 

 

 

 

DO NOT OPEN. NO USER

 

OFF

1

2

1

+4dB

 

SERVICABLE PARTS

 

 

47K

 

INSIDE. REFER SERVIC-

 

 

 

 

 

 

600

 

ING TO QUALIFIED SERVICE

 

 

 

 

 

 

 

 

PERSONNEL. TO PREVENT

FUSE

 

 

 

 

 

 

 

FIRE OR SHOCK HAZARD

 

+4dB

 

 

+4dB

 

 

DO NOT EXPOSE TO RAIN

 

 

 

 

 

 

OR MOISTURE

 

 

10K

PRE AMP OUT

600

 

 

 

 

 

AMP IN

2

 

 

 

ESUF

 

 

 

 

 

 

 

 

120 VOLT 6 AMP

 

CAUTION

 

!

 

 

 

CAUTION

220 VOLT 3.5 AMP

 

RISK OF ELECTRIC SHOCK

 

 

 

HEATSINK MAY BE HOT!

 

 

 

 

 

DO NOT BLOCK AIRFLOW

 

 

DO NOT OPEN

 

MON OUT

 

 

OR OVERHEATING MAY

 

 

 

 

 

OCCUR

 

 

SPEAKER OUTPUT

 

 

 

SERIAL NUMBER

 

 

MINIMUM 2

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEMBLED

 

 

 

 

 

 

 

 

IN R.O.K.

POWER RATING 120V/60Hz 450 W

The main connections here involve connecting the S63 speaker outputs to PA speakers and the Monitor output to the input of an external amplifier driving onstage monitors. Various microphones and line level signals are connected to channel mic and line inputs and a tape player is connected to the CD/Tape input. A signal processor is connected to Effects Send 2, with the resulting processed signal returned to Effects Returns 1 and 2.