The heating capacity of heat pump air conditioner on outdoor temperature

If the indoor or outdoor temperature is lower than the rated temperature (Indoor: 20 °C, outdoor: 7 °C) or the installation condition (Pipe length over standard of 5m, installation place and insulation etc.) is different, heating capacity may decrease even though the air conditioner performs normally. In this case, use extra heating apparatus.

Heating capacity

100 % of rated capacity

80 % of rated capacity

-10 °C

7 °C

24 °C

Outdoor temperature

01PREPARATION

Model specification (Weight and dimension)

Type

Model

Net weight

Net dimension (W x D x H)

 

 

 

 

Indoor Unit

AF24FSSDAWKN

31.0 kg

360 x 269 x 1948 mm

 

 

 

 

Outdoor Unit

AF24FSSDAWKX

62.5 kg

880 x 320 x 950 mm

 

 

 

 