Wiring work
Connecting power and communication cable
AP80S0A / AP0AS0A
ff3 phase 4 wires,
1.Remove the cover of the electrical component on the outdoor unit.
2.Connect the power cable (R, S, T, N) to the R, S, T, N of the terminal on the electrical component on the outdoor unit. (Power cable must be purchased separately.)
3.When tightening the screw on the terminal block, apply appropriate tightening torque to assemble cables to the terminal.
4.Install ELB [Earth Leakage breaker (for 4 wires)] for air conditioner. It must be selected according to the starting current of the compressor.
Indoor unit | Outdoor unit | Distributing board |
Earth
N1 L1 | F1 F2 |
Communication
terminal
Earth | N1 L1 F1 F2 |
R | S | T | N | L | Earth |
Earth
ELB for air
conditioner
R | S | T | N |
Communication cable | Power cable |
|
Communication cable between indoor and outdoor unit | Power supply cable |
•When using power supply (R, S, T, N) with ELB [Earth Leakage breaker (for 3 wires)] alone or ELB(for 3 wires) with NFB
Indoor unit
Earth | N1 L1 F1 F2 |
Outdoor unit
Disconnect the power cable
(It is connected as factory default)
Communication terminal
Earth | N1 L1 F1 F2 | R | S | T | N | L | Earth |
| Distributing board |
| |||
|
|
| ELB for air | ||
|
|
| conditioner | ||
L | N | Earth | R | S | T |
Communication cable | Power cable |
|
|
| |
Communication cable between indoor and outdoor unit | Power supply cable |