OPERATION RANGES
The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use.
MODE | OPERATING CONDITIONS | IF OUT OF CONDITIONS | |
| Indoor temp: 16°C~32°C | - A safety device will stop continuously the | |
COOL | Indoor humidity: below 80% | system functioning; | |
| - Condensation may occur on the indoor unit | ||
| |||
| Outdoor temp: 15°C~54°C | with risk to have either water blow off or drops | |
|
| on the floor; | |
HEAT | Indoor temp: below 27°C | - A safety device will stop continuously the | |
Outdoor temp: | system functioning; | ||
| |||
| Indoor temp: 16°C~32°C | - A safety device will stop continuously the | |
DRY | Indoor humidity: below 80% | system functioning; | |
| - Condensation may occur on the indoor unit | ||
| |||
| Outdoor temp: 15°C~54°C | with risk to have either water blow off or drops | |
|
| on the floor; | |
POWER SUPPLY | Single phase rated voltage | ||
minimum and maximum limit | 198V | ||
|
Any damage occurs out of condition specified cannot be covered by product warranty.
If the system works continuosly outside of conditions, its performace and reliability will be compromised.
TECHNICAL SPECIFICATIONS
| MODEL |
| AQ18DWAUMG |
| AQ24DWAUMG | AS18DWAUMG | AS24DWAUMG |
| ||||||||
| STANDARD |
| ISO | SASO |
|
| ISO | SASO | ISO | SASO | ISO | SASO |
| |||
|
|
| COOL | 18000 | 3750 | 24000 | 5000 | 18000 | 3750 | 24000 | 5000 |
| ||||
| CAPACITY |
| BTU/h | kcal/h |
| BTU/h | kcal/h | BTU/h | kcal/h | BTU/h | kcal/h | |||||
|
|
|
|
| ||||||||||||
|
| HEAT | 20000 | 4800 | 24000 | 6000 | - | - | - | - |
| |||||
|
|
|
| |||||||||||||
|
|
| BTU/h | kcal/h |
| BTU/h | kcal/h |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
| SOURCE |
|
|
| 220V~,60Hz |
|
| 220V~,60Hz | 220V~,60Hz | 220V~,60Hz |
| |||||
| CURRENT |
| COOL | 9.0A | 10.5A |
| 12.0A | 13.5A | 9.0A | 10.5A | 12.0A | 13.5A | ||||
|
| HEAT | 8.0A | 9.0A |
| 12.0A | 12.0A | - | - | - | - |
| ||||
|
|
|
|
| ||||||||||||
| POWER |
| COOL | 1894W | 2250W |
| 2600W | 2900W | 1894W | 2250W | 2600W | 2900W |
| |||
| CONSUMPTION |
| HEAT | 1800W | 1900W |
| 2600W | 2600W | - | - | - | - |
| |||
| REFRIGERANT |
| KIND | R22 |
|
|
| R22 | R22 | R22 |
| |||||
|
| QUANTITY | 1140g |
|
|
| 1350g | 1200g | 1250g |
| ||||||
|
|
|
|
|
| |||||||||||
|
|
| COOL | 9.5 | 6.6 | 9.2 | 6.8 | 9.5 | 6.6 | 9.2 | 6.8 |
| ||||
| EER |
| BTU/wh | BTU/wh |
| BTU/wh | BTU/wh | BTU/wh | BTU/wh | BTU/wh | BTU/wh | |||||
|
|
|
|
| ||||||||||||
|
| HEAT | 11.11 | 10.0 | 9.2 | 9.0 | - | - | - | - |
| |||||
|
|
|
| |||||||||||||
|
|
| BTU/wh | BTU/wh |
| BTU/wh | BTU/wh |
| ||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| INDOOR | DB(C/H) | 27°C/20°C | 29°C/21°C | 27°C/20°C | 29°C/21°C | 27°C/20°C | 29°C/21°C | 27°C/20°C | 29°C/21°C |
| ||||
| TEMPERATURE | WB(C/H) | 19°C/ - | 19°C/ - |
| 19°C/ - | 19°C/ - | 19°C/ - | 19°C/ - | 19°C/ - | 19°C/ - |
| ||||
| OUTDOOR | DB(C/H) | 35°C/7°C | 46°C/7°C |
| 35°C/7°C | 46°C/7°C | 35°C/7°C | 46°C/7°C | 35°C/7°C | 46°C/7°C |
| ||||
|
|
| ||||||||||||||
|
| WB(C/H) | 24°C/6°C | 24°C/6°C |
| 24°C/6°C | 24°C/6°C | 24°C/6°C | 24°C/6°C | 24°C/6°C | 24°C/6°C | |||||
|
| INDOOR | NET | 13 | 13 | 13 | 13 |
| ||||||||
| WEIGHT | GROSS | 16 | 16 | 16 | 16 |
| |||||||||
| OUTDOOR | NET | 39 | 39 | 56 | 56 |
| |||||||||
|
|
| ||||||||||||||
|
| GROSS | 43 | 43 | 58 | 58 |
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| appendix _33 | ||