Technical Specifications
◆These results are measured at the standard piping length. The standard length is 7.5m(24ft. 7in).
| MODEL |
| AQ30✴✴BC |
| ||
|
|
|
|
|
| |
Performance | Capacity Cooling |
| Btu/h | 30000 |
|
|
Ratings |
|
|
|
|
|
|
Capacity Heating |
| Btu/h | 30000 |
|
| |
|
|
|
| |||
|
|
|
|
|
|
|
| HSPF |
|
| 6.8 |
|
|
|
|
|
|
|
|
|
| SEER |
|
| 10.0 |
|
|
|
|
|
|
|
|
|
| Moisture Removal |
| Pts/h | 7.2 |
|
|
|
|
|
|
|
|
|
| Air FLOW(Cooling, HIGH) |
| CFM | 671 |
|
|
|
|
|
|
|
|
|
| Air FLOW(Heating, HIGH) |
| CFM | 706 |
|
|
|
|
|
|
|
|
|
| Sound |
| dB | 58 |
|
|
|
|
|
|
| ||
Electrical | Power source |
|
| |||
Data |
|
|
|
|
|
|
Min.Ampacity |
| A | 14 |
|
| |
|
|
|
| |||
|
|
|
|
|
|
|
| Cooling Watts |
| W | 3100 |
|
|
|
|
|
|
|
|
|
| Heating Watts |
| W | 3100 |
|
|
|
|
|
|
|
|
|
Refrigeration | Connections |
|
| Flare |
|
|
Lines |
|
|
|
|
|
|
Liquid Line O. D. |
| mm(in) | 6.35 (1/4) |
|
| |
|
|
|
| |||
|
|
|
|
|
|
|
| Suction Line O.D. |
| mm(in) | 15.88 (5/8) |
|
|
|
|
|
|
|
|
|
| Factory |
| m(ft) | 7.5 ( 24 34 | ) |
|
|
|
|
|
|
|
|
| Max. Line length |
| m(ft) | 20.0 ( 65 12 | ) |
|
|
|
|
|
|
|
|
| Max. Height Difference |
| m(ft) | 8.0 ( 26 14 | ) |
|
|
|
|
|
|
| |
Dimensions | INDOOR UNIT |
| AQ30✴✴BC |
| ||
& Weight |
|
|
|
|
|
|
W X H X D |
| mm(in) | 1279 x 345 x 229 | |||
|
| |||||
|
| ( 5083 x 13 58 x 9 ) |
| |||
|
|
|
| |||
|
|
|
|
|
|
|
| Net Weight |
| Ibs | 44.1 |
|
|
|
|
|
|
|
| |
| OUTDOOR UNIT |
| UQ30✴✴BC |
| ||
|
|
|
|
| ||
| W X H X D |
| mm(in) | 880 x 890 x 310 | ||
|
| 5 | 1 | ) | ||
|
|
|
| (34 8 x 35 x 12 4 | ||
|
|
|
|
|
|
|
| Net Weight |
| Ibs | 183 |
|
|
|
|
|
|
|
|
|
✳ Standard rating conditions Cooling
| Indoor | Outdoor | ||
| DB | WB | DB | WB |
°F | 80 | 67 | 95 | 75 |
°C | 26.7 | 19.4 | 35.0 | 23.9 |
Heating | Indoor | Outdoor | ||
| ||||
| DB | WB | DB | WB |
°F | 70 | 60 | 47 | 43 |
°C | 21.1 | 15.6 | 8.3 | 6.1 |