Samsung AQ30C1(2)BC installation manual Auxiliary Circuit Breaker, Electrical Work, Model, AQ30BC

Models: AQ30C1(2)BC

1 48
Download 48 pages 29.74 Kb
Page 40
Image 40
Auxiliary Circuit Breaker

INSTALLING THE OUTDOOR UNIT

Auxiliary Circuit Breaker

Outdoor unit

Distribution

 

board

 

Auxiliary

 

power s/w

Auxiliary circuit breaker should be installed near outdoor unit so that each access is possible. Main/outdoor power supply cable are connected to upper/lower terminal of auxiliary circuit breaker.

It is necessary that the conduit kit for power supply to the outdoor unit be installed between auxiliary power S/W and the outdoor unit. (the conduit kit is optional)

Electrical Work

1The supply voltage must be the same as the rated voltage of the air conditioner.

2Prepare the power souce for exclusive use with the air conditioner.

3Use 15 amperes time delay fuse or circuit breaker.

MODEL

AQ30✴✴BC

 

 

Power supply

208-230V~/60Hz

Single phase

 

 

 

Power cable

3G AWG 12

 

 

 

Assembly cable

5G AWG 14

+ 2G AWG 18

 

 

 

Operating current(C/H)

14A

/ 14A

 

 

Starting Current

80A

 

 

 

Power consumption (C/H)

3100W

/ 3100W

 

 

 

When using the special NFB, use the NFB to bear the capacity of the air conditioner.

Otherwise, the shot circuit in the NFB may occur.

E-40

Page 40
Image 40