Samsung AQ30C1(2)BC installation manual Fixing the Unit in Position

Models: AQ30C1(2)BC

1 48
Download 48 pages 29.74 Kb
Page 42
Image 42
Fixing the Unit in Position

INSTALLING THE OUTDOOR UNIT

Installing and Connecting the Outdoor Unit Drain Hose

When using the air conditioner in the heating mode, ice may accumulate. During de-icing, the condensed water must be drained off safely. Consequently, you must install a drain hose on the outdoor unit, following the instructions below.

1 Insert the drain plug into the drain hole on the underside of the outdoor unit.

Drain hole

2Connect the drain hose to the drain plug.

3 Ensure that the drained water runs off correctly and safely.

Fixing the Unit in Position

Unit : mm(inch)

660(26)

)

3 8

340 (13

Rubber leg

The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).

1Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

2Attach the outdoor unit to the appropriate support using anchor bolts.

3If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit, so that the fan can operate correctly.

Certainly fix up its rubber leg, in order to prevent its vibration and noise.

E-42