COMPLETING THE INSTALLATION
Performing the Gas Leak Tests
CD
A
B
Make sure to check for gas leaks before completing the installation process (connecting the assembly pipe and hose between indoor unit and outdoor unit, insulating the cables, hose and pipe, and fixing the indoor unit to the installation plate)
To check for gas leaks on the... | Using a leak detector, check the... |
|
|
Indoor unit | Flare nuts at the end of sections |
| C and D. |
|
|
Outdoor unit | Valves on sections A and B. |
|
|