![Changing Direction of the Drain Hose](/images/new-backgrounds/36051/3605121x1.webp)
INSTALLING THE AIR CONDTIONER
Changing Direction of the Drain Hose
ENGLISH
You can select the direction of the drain hose, depending on where you want to install the indoor unit.
1Detach the rubber cap with the flyer.
2Detach the drain hose by pulling it and turning to the left.
3Insert the drain hose by fixing it into the groove of the drain hose and the outlet of the drain pan.
4Attach the rubber cap with a screwdriver by turning it to the right until it fixes to the end of the groove.
One of the diagrams has an illustration with the words “Screws hole” that should be changed to “Screw hole.”
Screws hole
Screw
Drain hose
Drain pan outlet
Rubber cap
Installing and Connecting the Drain Hose of the Outdoor Unit
While heating, ice may accumulate. During the process of defrosting, check if condensation draining is adequate. For adequate draining, do the following:
1Insert the drain plug into the drain hole on the underside of the outdoor unit.
There are “A” drain holes on the underside. You can use any hole for your convenience.
| Model | “A” |
|
| AQV09J | 3 |
|
| AQV12J |
| |
|
|
| |
| AQV18J | 1 |
|
| AQV24J |
| |
|
|
| |
|
|
|
|
2Connect a drain hose to the drain plug.
Drain hole
3Ensure that condensation draining is adequate.