• The flare nuts are attached to the end of each pipe of an evaporator or a service port.

Use the nuts when connecting the pipes.

The wire assembly cable is optional. If it is not supplied, use the standard cable.

The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below.

Optional accessories

The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner.

Insulated Assembly Pipe,

Insulated Assembly Pipe,

Insulated Assembly Pipe,

PE T3 Foam Tube

Vinyl Tapes (2)

Drain Hose,

Ø6.35 mm x 5 m (1) ✴✴12/18✴✴

Ø12.70 mm x 5 m (1)

Ø15.88 mm x 4 m (1)

Insulation (1)

length 2 m (1)

Ø6.35 mm x 4 m (1) ✴✴24✴✴

✴✴12/18✴✴

✴✴24✴✴

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Putty 100 g (1)

Pipe Clamps A (3)

Pipe Clamps B (3)

Cement Nails (6)

M4 x 25 Tapped

Screws (6)

4-wire

Assembly Cable (1) ✴✴12/18/24✴✴

• If these accessories are supplied, they will be in the accessory box.

Tools required for installation

General Tools

• Vacuum Pump(Backward flowing prevention)

• Manifold Gauge

• Stud Finder

• Torque Wrench

• Pipe Cutter

• Reamer

• Pipe Bender

• Spirit Level

• Screw Driver

• Spanner

• Drill

• L Wrench

• Measuring Tape

Tools for test operations

 

 

 

• Thermometer

• Resistance Meter

 

• Electroscope

 

Fixing the installation plate

You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, you must determine the position of the 65 mm hole through which the cable, pipe and hose pass to connect the indoor unit to the outdoor unit.

When facing the wall, the pipe and cable can be connected from the:

• Right (A)

Direction of pipe

 

 

 

• Left (B)

 

 

• Underside_right (C)

A

B

• Rear_right or left (D)

D

D

 

C

 

You can install the refrigerant pipe in the left/right/bottom, or the rear side of the indoor unit.

• If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite direction as shown. Otherwise, the pipe may be damaged in the process.

English-36

MG_GOOD_R-410A_A3050_IB&IM_EN_DB68-04540A.indd 36

9/1/2014 5:11:04 PM

Page 36
Image 36
Samsung AR24JQFSBWKNMG Fixing the installation plate, Optional accessories, Tools required for installation General Tools