Outdoor Unit Installation

Step 3.1 Fixing the outdoor unit in place

X

Y

Rubber leg

 

 

(Unit : mm)

 

 

 

Model

X

Y

 

 

 

✴✴18✴✴

660

340

✴✴24KR/MR✴✴

 

 

 

 

 

✴✴24KQ✴✴

645

340

 

 

 

1Place the outdoor unit as directed on the top of the unit to let the discharged air out properly.

2Fix the outdoor unit in level to an appropriate support using anchor bolts.

NOTE

Secure the rubber legs to help prevent the generation of noise and vibration.

If the outdoor unit is exposed to strong winds, install shield plates around the outdoor unit so that the fan can operate correctly.

NOTE

Make sure that the wall can support the weights of the rack and the outdoor unit.

Install the rack close to the column as much as possible.

Step 3.2 Connecting the cables and the refrigerant pipes

✴✴18KR/MR✴✴✴✴24✴✴

N(1)

1

N(1)

1

2

✴✴18KQ/MQ✴✴

N(1)

1

2

3

Optional: Fixing the outdoor unit to a wall with a rack

Soft rubber designed to cut off vibration from rack to wall (not supplied with product)

CAUTION

• Be sure to fix the power cables and communication cable with a cable clamp.

Installation

Soft rubber designed to cut off residual vibration from outdoor unit to rack (not supplied with product)

English 45

Page 46
Image 46
Samsung AR24MRJSRWK/MG, AR18MQJSBWKXMG manual Outdoor Unit Installation, Connecting the cables and the refrigerant pipes