Precautions when handling the cabinetsRestrictions when installing cabinets

[Caution to prevent external shock and dropping of the product]

After removing the protective brackets, be careful not to expose the product to external shocks or vibrations. Make sure that the product is not dropped from any height.

Be careful not to expose the product to vibrations or external shocks when it is lying flat on the floor.

[Caution to prevent damage to corners]

Take extra care to ensure that the corners of a cabinet do not get damaged.

After removing the protective brackets, do not place the product on the floor with the LED facing down.

[Caution to prevent damage to the LED from static]

Do not touch the product without anti-static gloves.

For each SBB-IS08E, the following install configurations are possible: a maximum of 18 IL015E, IS015F devices, a maximum of 32 IL020F, IS020F devices or a maximum of 50 IL025E, IS025F devices.

To obtain Full HD 50/60 Hz picture quality, the following install configurations are possible: IL015E, IS015F devices using a 3*6 layout, IL020F, IS020F devices using a 4*8 layout or IL025E, IS025F devices using a 5*10 layout.

IL015E / IS015F

IL020F / IS020F

IL025E / IS025F

26