Samsung LH43PHFPMGC/EN manual Volume control, Input source control, Setting the volume Set Volume

Models: LH49PHFPBGC/EN LH55PHFPMGC/EN

1 90
Download 90 pages 39.46 Kb
Page 24
Image 24
Volume control

Chapter 2. Device setup

Ack

Header

Command ID

Data

Ack /

r-CMD

Val1

Checksum

 

 

 

length

Nak

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

3

‘A’

0x11

"Power"

 

 

 

 

 

 

 

 

 

“Power”: Power code to be set on a product.

Nak

Header

Command ID

Data

Ack /

r-CMD

Val1

Checksum

 

 

 

length

Nak

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

3

‘N’

0x11

“ERR”

 

 

 

 

 

 

 

 

 

“ERR” : A code showing what error has occurred.

Volume control

Function

The volume of a product can be adjusted using a PC.

Viewing volume state (Get Volume Status)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

0x12

 

0

 

 

 

 

 

 

Setting the volume (Set Volume)

Header

Command

ID

Data

Data

Checksum

 

 

 

length

 

 

 

 

 

 

 

 

0xAA

0x12

 

1

“Volume”

 

 

 

 

 

 

 

“Volume”: Volume value code to be set on a product. (0-100)

24

Ack

Header

Command ID

Data

Ack /

r-CMD

Val1

Checksum

 

 

 

length

Nak

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

3

‘A’

0x12

“Volume”

 

 

 

 

 

 

 

 

 

“Volume”: Volume value code to be set on a product. (0-100)

Nak

Header

Command ID

Data

Ack /

r-CMD

Val1

Checksum

 

 

 

length

Nak

 

 

 

 

 

 

 

 

 

 

 

0xAA

0xFF

3

‘N’

0x12

“ERR”

 

 

 

 

 

 

 

 

 

“ERR” : A code showing what error has occurred.

Input source control

Function

The input source of a product can be changed using a PC.

Viewing input source state (Get Input Source Status)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

0x14

 

0

 

 

 

 

 

 