ALARM OUT
Each ALARM input corresponds to one of the 3 ALARM OUT.
ALARM OUT |
|
ALARM1 | 1 |
ALARM2 | 2 |
ALARM3 | 3 |
ALARM4 | 2 |
MOTION | 1 |
EXIT | QUIT |
ALARM PATTERN
This sets the operation of PATTERN movements when inputting ALARM.
When the ALARM is working, it will stay in the PRESET location corresponding the ALARM for the DWELL TIME and the ALARM connected to the PATTERN will continuously operate the PATTERN movements.
When the ALARM is inputted the correspondence will be as follows: ALARM1 input to PRESET 1, ALARM 2 input to PRESET 2, ALARM3 input to PRESET 3, ALARM 4 input to PRESET 4, and MOTION input to PRESET 5.
ALARM PATTERN
ALARM1 OFF
ALARM2 OFF
ALARM3 1
ALARM4 2
MOTION 3
EXITQUIT
The OFF in the Setup Menu does not operate the PATTERN, and it means 1 ➞ PATTERN1, 2 ➞ PATTERN 2, 3 ➞ PATTERN 3, HALF1 ➞ continuous motion of PATTERN 1 + PATTERN 2, HALF 2 ➞ continuous motion of PATTERN 2 + PATTERN 3 and FULL ➞ continuous motion of PATTERN 1+PATTERN2+PATTERN3.
AUX OUT CONTROL
This sets the ALARM OUT motion to continue or act only when the ALARM is working.
If it is set to OFF the ALARM OUT motion will operate only when the ALARM is working. (Active "Low"), and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.
AUX OUT
OUT1 OFF
OUT2 OFF
OUT3 ON
EXITQUIT