Samsung SCC-643P manual Alarm SET, Alarm Priority SET, Alarm in SET

Models: SCC-643P

1 56
Download 56 pages 18.77 Kb
Page 48
Image 48

PATTERN can be set upto 3. Choose 1, 2, or 3 with the left or right key in the "PATTERN SET" and press [ENTER] to get into the PATTERN set up screen. From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the MANUAL movements and after 30 seconds it will return to a higher menu. If you want to finish set up before the 30-second ends, press [ENTER].

5. ALARM SET

It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.

It recognizes the ALARM signal input as an ALARM signal when it continues more than 150ms for a time and each ALARM movement time is decided depending on it's correspondence to the DWELL TIME of the PRESET and PATTERN connected.

* * MAIN MENU * *

CAMERA...

VIDEO SET...

PRESET...

AUTO MODE...

ALARM SET...

OTHER SET...

Press

[Enter]

( ALARM SET)

ALARM PRIORITY SET.. ALARM IN SET.. ALARM OUT SET.. ALARM PATTERN SET.. AUX OUT CONTROL..

RET

ALARM PRIORITY SET

This sets the priority of the 4 ALARM inputs so ALARM can work corresponding to the priority. The priority of the DEFAULT is ALARM1: 1, ALARM2: 2, ALARM3: 3, ALARM4: 4, MOTION: 5. If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.

ALARM IN SET

This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.

ALARM PRIORITY

ALARM1 1

ALARM2 2

ALARM3 3

ALARM4 4

EXITQUIT

ALARM IN

ALARM1 NO

ALARM2 NC

ALARM3 NO

ALARM4 NC

EXITQUIT

3-20

Page 48
Image 48