Installation

Power Connection

Please, check the voltage and current capacity of rated power carefully. Rated power is indicated in the back of main unit.

Power Mode

Input Voltage Range

Power Consumption

C6323/ C6325

C7325

 

 

 

 

 

 

DC 12V

DC 11V ~ 15V

8 W

12W

 

 

 

 

AC24V

AC 20V ~ 29V

10W

21W

 

 

 

 

RS-485 Communication

For PTZ control, connect this line to keyboard and DVR. To control multiple cameras at the same time, RS-485 communication lines of them is connected in parallel as shown below.

Keyboard Controller DVR

Video Connection

Connect with BNC coaxial cable.

Alarm Input Connection

Sensor Input

If you want to use Alarm Input, the types of sensor must be selected in OSD menu. The sensor types are Normal Open and Normal. If sensor type is not selected properly, the alarm can be activated reversely.

Normal Open

Sensor output is turned ON when

(N.O)

sensor is activated

INTERNAL

IN1

Normal Close

Sensor output is turned OFF when

(N.C)

sensor is activated

IN 2

IN COM

• Relay Output

Internal

Relay Out

Power

Relay Out

It is noted that short circuit between GND and Input pin means alarm activation.

There are 4 Alarm Outputs and all of them are Relay contact type. Therefore, you do not have to care about polarity, AC/DC, and isolations between channels. Care must be taken for the power capacity of relay contact written above.

20 – 10X MINI SMART DOME CAMERA

Page 20
Image 20
Samsung SCC-C7325, SCC-C6325, SCC-C6323 Power Connection, RS-485 Communication, Video Connection, Alarm Input Connection