Installation
DIP SWITCH SETUP
Before you install the camera, you should set the DIP switches to confi gure the camera ID, Baud rate, and communication protocol.
Protocol | Buad Rate |
Auto Select |
|
Terminate
ID Setting (1~255)
❖Camera ID Setup
•ID number of camera is set using binary number. The example is shown bellow.
Pin | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
|
|
|
|
|
|
ID Value | 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 |
|
|
|
|
|
|
|
|
|
ex) ID=5 | on | off | on | off | off | off | off | off |
ex) ID=10 | off | on | off | on | off | off | off | off |
|
|
|
|
|
|
|
|
|
•The range of ID is 0~255. Factory default of Camera ID is 1.
•If you want to control a certain camera, you must match the camera ID with Cam ID setting of DVR or Controller.
❖Communication Protocol Setup
ON ON
1 2 3 4 5 6 7 8
•Select the appropriate Protocol with DIP switch combination.
| Switch State |
| Protocol | |
|
|
|
| |
Pin1 | Pin2 | Pin3 | Pin4 |
|
|
|
|
|
|
OFF | OFF | OFF | OFF | Auto Protocol |
ON | OFF | OFF | OFF | |
OFF | ON | OFF | OFF | |
ON | ON | OFF | OFF | Samsung |
• If you set the protocol as Auto Protocol, camera | ||||||||
will automatically recognize the kind of Protocol. | ||||||||
• Auto Protocol supports | ||||||||
• If you want to control using DVR or system |
| |||||||
keyboard, their protocol must be identical to | ||||||||
camera. Otherwise, you can not control the camera. | ||||||||
• If you changed camera protocol by changing DIP S/W, | ||||||||
the change will be effective after you reboot the camera. | ||||||||
• Factory default of protocol is “Auto Protocol | ||||||||
❖ Communication Baud rate Setup | ENG | |||||||
|
|
|
|
|
|
|
| |
ON | ON |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
•Select the appropriate Baud rate with DIP switch combination.
| Switch State |
| Protocol | ||
|
|
|
|
| |
Pin5 |
| Pin6 |
| Pin7 |
|
|
|
|
|
|
|
OFF |
| OFF |
| OFF | 2400 BPS |
ON |
| OFF |
| OFF | 4800 BPS |
OFF |
| ON |
| OFF | 9600 BPS |
ON |
| ON |
| OFF | 19200 BPS |
OFF |
| OFF |
| ON | 38400 BPS |
• Factory default of Baud rate is “9600 BPS”
English – 13