The voltage derating factor should be as great as possible. Under normal conditions, the operating
voltage should be reduced to 50% or less of the rating. It is recommended that the operating
voltage be 30% or less of the rating, particularly when the tantalum capacitors are used in a low-
impedance circuit (see Figs. 1, 2, and 3).
For circuits in which a switching, charging, discharging, or other momentary current flows, it is
recommended that the operating voltage be 30% or less of the rating, with a resistor connected in
series to limit the current to 300 mA or less.
When the tantalum capacitors are to be used at an ambient temperature of higher than 85, the
recommended operating range shown in Fig. 3 should not be exceeded.
SCL Series

APPLICATION MANUAL

OPERATING VOLTAGE

The operational attentions to the use of the tantalum capacitors are as follows:
- Electrical
- Environmental
- Conditions for mounting on equipment and circuit boards
- Mechanical vibration, shock
If the tantalum capacitors are used without satisfying any one of these conditions, the probability of
short-circuiting, leakage current, ignition or other problems to occur increases. To avoid such
problems, observe the following precautions when using the tantalum capacitors.
-
Power
supply
circuit
~
+
+
Fig. 1

Power supply filter

IC
+
-
+
Fig. 2

Power supply bypass

OPERATING T EMPERATURE
-40-20020406085100125
-55
100
80
60
40
20
0
Fi
g
.3