SCL Series
Soldering with a soldering iron
The use of a soldering iron should be avoided wherever possible. If it is
unavoidable, follow the instructions set forth in Table 5. The time of soldering with an iron
should be one.
Table 5
Cleaning after Mounting
The following solvents are usable when cleaning the capacitors after mounting. Never use
a highly active solvent.
- Halogen organic solvent (HCFC225, etc.)
- Alcoholic solvent (IPA, ethanol, etc.)
- Petroleum solvent, alkali saponifying agent, water, etc.
Circuit board cleaning must be conducted at a temperature of not higher than 50°C and for
an immersion time of not longer than 30 minutes. When an ultrasonic cleaning method is
used, cleaning must be conducted at a frequency of 48 kHz or lower, at an vibrator output
of 0.02 W/cm3, at a temperature of not higher than 40°C, and for a time of 5 minutes or shorter.
NOTE 1: Care must be exercised in cleaning process so that the mounted capacitor will not come
into contact with any cleaned object or the like or will not get rubbed by a stiff brush or
the like. If such precautions are not taken particularly when the ultrasonic cleaning
method is employed, terminal breakage may occur.
NOTE 2: When performing ultrasonic cleaning under conditions other than stated above, conduct
adequate advance checkout.
OTHER
For further details, refer to EIAJ RCR-2368, Precautions and Guidelines for Using Electronic Device
Tantalum Capacitors.
If you have any questions, feel free to contact your local SAMSUNG ELECTRO-MECHANICS agent.
Soldering-iro n tip temperature 350MAX

Time 3secMAX

Soldering-iro n power 30 W MAX