Soldering with a soldering iron

The use of a soldering iron should be avoided wherever possible. If it is

unavoidable, follow the instructions set forth in Table 5. The time of soldering with an iron should be one.

Table 5

Soldering-iron tip temperature

350MAX

 

 

Time

3 sec MAX

 

 

Soldering-iron power

30 W MAX

 

 

Cleaning after Mounting

The following solvents are usable when cleaning the capacitors after mounting. Never use a highly active solvent.

-Halogen organic solvent (HCFC225, etc.)

-Alcoholic solvent (IPA, ethanol, etc.)

-Petroleum solvent, alkali saponifying agent, water, etc.

Circuit board cleaning must be conducted at a temperature of not higher than 50°C and for an immersion time of not longer than 30 minutes. When an ultrasonic cleaning method is used, cleaning must be conducted at a frequency of 48 kHz or lower, at an vibrator output

of 0.02 W/cm3, at a temperature of not higher than 40°C, and for a time of 5 minutes or shorter.

NOTE 1: Care must be exercised in cleaning process so that the mounted capacitor will not come into contact with any cleaned object or the like or will not get rubbed by a stiff brush or the like. If such precautions are not taken particularly when the ultrasonic cleaning method is employed, terminal breakage may occur.

NOTE 2: When performing ultrasonic cleaning under conditions other than stated above, conduct adequate advance checkout.

OTHER

SCL Series

For further details, refer to EIAJ RCR-2368, Precautions and Guidelines for Using Electronic Device Tantalum Capacitors.

If you have any questions, feel free to contact your local SAMSUNG ELECTRO-MECHANICS agent.