Digital Multiplexer

- The following is displayed if pressing the “ENTER” button with the blinking position placed at the “SPOT OUT...”:

[SPOT OUT]

CH1 : 02 CH2 : 00

CH3 : 00 CH4 : 00

CH5 : 00 CH6 : 00

CH7 : 00 CH8 : 00

CH9 : 00 CH10 : 00

CH11 : 00 CH12 : 00

CH13 : 00 CH14 : 00

CH15 : 00 CH16 : 00

ALARM S/W TIME : 02

ENGLISH

You can set the sequence time of SPOT output.The blinking indication moves if pressing “”, “” button.

The setting value is changed if pressing “ ”, “ ” button. CH1~CH16 : 0 to 30 seconds.

Alarm S/W TIME : 01 to 30 seconds.

The changed setting value is stored if pressing the “SET” button and you can return to the “MON OUT SET” menu.

The channel of LOSS or “ 0 ” of sequence time will be skipped in the SPOT output sequence.

SPOT OUTPUT on alarm

When the alarm is activated, only the alarmed channel will be output. On single alarm : output only the alarmed channel.

On multiple alarms : output alarmed channels in turn at intervals of set ALARM S/W TIME. (Even the sequence time of the alarmed channel is set as “ 0 ” then will be SPOT output.)

- The following is displayed if pressing the “ENTENR” button with the blinking position placed at “SEQUENCE….”:

[SEQUENCE]

CH1 : 02

CH2 : 02

CH3 : 02

CH4 : 02

CH5 : 02

CH6 : 02

CH7 : 02

CH8 : 02

CH9 : 02

CH10: 02

CH11: 02

CH12: 02

CH13: 02

CH14: 02

CH15: 02

CH16: 02

Set the indication time (second) of each channel in the automatic conversion mode.

The blinking indication moves if pressing “”, “” button.

The setting value is changed if pressing “”, “ ” button. CH1 ~ CH16 : 0 ~ 30

“0” is skipped irrespective of existence of channel loss in the automatic conversion mode.

The changed setting value is stored if pressing the “SET” button and you can return to the “MON OUT SET” menu.

5-4