Digital Multiplexer

Chapter 7. Occurrence and handling of alarm, loss, motion

1.Alarm occurrence conditions

The following events occur if alarm occurs since the sensor is connected to the alarm input terminal on the backside:

1)Warning sounds (if buzzer turns “ON”).

2)Alarm information (date and time when alarm occurs) is recorded on the alarm list.

3)“RESET” LED blinks.

4)The alarm output (HOT, COLD) signal is active for the alarm hold time.

5)The record times of the channel that alarm occurs increase.

6)Display character of “ALARM” or “A” appears (if the alarm information turns “ON”).

7)Alarm continues for the alarm hold time that is set in the program mode.

Alarm holds time: Time performing alarm operation after recognizing alarm.

2.Alarm release

The alarm status is released if pressing the “RESET” button when alarm occurs or the alarm holds time setting passes.

3.Alarm record

Perform the alarm weight value record in the chapter 6.

4.Alarm signal standard

You can view record output when alarm occurs during record.

For example, if record status have the following conditions:

Currently perform record in the TLV mode on the time lapse VCR.

Set the “REC TYPE” to “NOR” in the “5. ALARM SET” of the “program mode”.

The record output until release after the alarm occurs is as follows:

VCR TRIG

 

TRIG override

 

 

 

 

Record output

TLV operation

NOR operation

TLV

operation

 

 

 

ALARM/MOTION OUT

 

 

 

Output

 

 

 

ALARM RESET

 

 

 

Output

 

 

 

More than 150ms

Alarm occurrence

Alarm reset

7-1