Diagnostics Test

Diagnostics Test

Simultaneously press the LIGHT and OFF keys for 3 seconds. The diagnostics screen will appear in the LCD display.

Sample Diagnostics Screen

Displayed Information

MODEL - Identified at power-up by the keytail ID option.

CODE VERSION - The date the code file was sent to GEA for testing (MM-DD-YY).

HUMIDITY SENSOR - The CUR (current), DET (detection point), MIN (minimum), MAX (maximum) humidity sensor data will update continuously.

The CUR value is the present A/D value of the sensor. DET is the value at the moment the humidity detection point was reached. MIN is the lowest humidity point measured during entire feature’s run. MAX is the highest humidity value measured during the feature’s run. These data points are the dynamic measurements of the sensor, not the calculated values.

Pressing the DONE key terminates the diagnostic screen. The screen returns to the previous or HOME screen. The diagnostic screen will timeout and return to the previous screen after receiving no input for 5 minutes.

Error Message

F1 Convection - Open thermal sensor

F2 Convection - Shorted thermal sensor

F3 - Keypanel shorted for more than 60 seconds

F4 - Open humidity sensor

F5 - Shorted humidity sensor

F10 - Shorted touch panel

Note: Any “F” code will cause an error sound to beep for 3 cycles. One cycle will sound 2 seconds on, 1 second off.

Sample “F” Code page

Demonstration Mode

In demonstration mode, everything will operate on the unit except the high voltage section.

To enter the demonstration mode, disconnect the power for 30 seconds then reapply power. Simultaneously press the HELP screen pad and the BOOST button for 3 seconds. The word DEMO will appear in the LCD display.

To exit the demonstration mode, disconnect the power for 30 seconds then reapply power.