Interlocks (Door Latch Switches)

Using a small screwdriver, release the tab and remove the door interlock switch from the door switch bracket. Disconnect the electrical connector.

Interlocks (Door Latch Switches)

Interlocks are designed as follows:

Primary Interlock System Test

WARNING: Disconnect the oven from the power supply.

Door Sensing Switch

Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed.

Power Relay

Disconnect 2 wires from the tab terminals on the circuit board provided in the control panel assembly. The tab terminals are located in the area of the circuit board on the component side, and are connected to the contacts of the power relay. Check the state of the relay contacts using an ohmmeter. The relay contacts should be open. If the relay contacts are closed, replace the circuit board.

Primary Interlock Switch Test

Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the primary interlock switch.

Note: The primary interlock switches are not adjustable and must be replaced if test is failed.

Primary Interlock System TestDoor Sensing Switch (top)

Door Sensing Switch Monitor Interlock Switch (middle)

Power RelayPrimary Interlock Switch (bottom)

Door Sensing Switch:

Door Closed - 0 ohms

Door Open - Infinite ohms

Monitor Interlock Switch:

Door Closed - Infinite ohms

Door Open - 0 ohms

Primary Interlock Switch:

Door Closed - 0 ohms

Door Open - Infinite ohms

Note: Remove the wires from the switches before checking continuity.