GE JVM2070_H manual Top Stirrer Motor, Removal

Models: JVM2070_H

1 33
Download 33 pages 34.68 Kb
Page 11
Image 11
Top Stirrer Motor

Top Stirrer Motor

Resistance through the top stirrer motor from the power cord (L) to CN04 pin 5 is approximately

6.7ohms. Isolated, the top stirrer motor is approximately 7.0 ohms. The door (primary interlock) must be closed to complete circuit. Check motor circuit for 21 VAC when operating.

Removal

Remove the microwave (see Microwave Removal and Component Access).

Disconnect the side stirrer motor electrical connector. Remove 2 screws and ground wire from the duct and move the duct out of the way.

Top Stirrer

Removal

Open the oven door. Pull the plastic rivet out of the stirrer cover. Rotate the stirrer cover CCW until it stops and remove the stirrer cover.

Rivet

Remove the stirrer.

Note: When assembling, assure that the stirrer rides on the support in the cover.

Disconnect the electrical connector from the motor. Remove 2 screws that hold the motor in place and remove the motor.

Disconnect Top Stirrer

– 11 –