Magnetron Does Not Work

Magnetron Does Not Work

Does continuity exist between the HV

transformer black wire and power cord with primary interlock closed (door closed)?

Yes

Does continuity exist between the HV

transformer blue wire and secondary interlock-2

blue wire thru HV transformer fuse?

Yes

Does continuity exist between the secondary

interlock-2 blue wire and power cord?

Yes

Does continuity exist between the HV transformer white wire to power cord thru secondary interlock - 1 (door closed) and monitor interlock switch open (door closed)?

Yes

Replace the main control board.

Does the magnetron work?

No

Replace the HV capacitor.

Does the magnetron work?

No

Replace the HV transformer.

Does the magnetron work?

No

Replace the magnetron.

Replace the primary interlock switch or repair

No 2 - White faulty wiring between the HV transformer and the primary interlock switch.

No

 

Replace the HV transformer fuse or

 

repair faulty wiring.

No

Repair faulty wiring.

No

Repair faulty wiring.

 

1

1

- Red

 

2

2 - White

3 - Blue

4

- Black

2

3

4

– 27 –

Page 27
Image 27
GE JVM2070_H manual Magnetron Does Not Work, White, Blue, Black