2 Troubleshooting Procedures

2.3 Power Supply Troubleshooting

Procedure 2 Error Code Check

If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The blink pattern indicates an error as shown below.

‰

Start

Off for 2 seconds

‰ Error code (8 bit)

 

 

“1”

ON for one second

 

“0”

ON for half second

 

Interval between data bits

Off for half second

The error code begins with the least significant digit.

Example:

Error code 13h (Error codes are given in hexadecimal format.)

 

 

 

 

Check 1 Convert the DC IN icon blink pattern into the hexadecimal error code and compare it to the tables below. Then go to Check 2.

Error code

Where Error occurs

 

 

1*h

Adapter (AC Adapter, DS)

 

 

2*h

1st battery

3*h

2nd battery

4*h

S3V output

 

 

5*h

E5V output

 

 

6*h

E3V output

 

 

7*h

PPV output

 

 

8*h

1R8-B1V output

 

 

9*h

PPV output

 

 

A*h

PTV output

 

 

B*h

1R5-E1V output

 

 

C*h

PGV output

 

 

D*h

VG1R8-P1V output

 

 

E*h

PTV output

 

 

F*h

-

 

 

2-8