2.3 Power Supply Troubleshooting

2 Troubleshooting Procedures

‰DC power supply (AC adapter)

Error code

Meaning

 

 

10h

AC Adapter output voltage is over 16.5V.

 

 

11h

Common Dock output voltage is over 16.5V.

 

 

12h

Current from the DC power supply is over 7.00A.

 

 

13h

Current from the DC power supply is over 0.5A when there is no load.

 

 

14h

Abnormal current has been sensed.

 

 

‰Main Battery

Error code

Meaning

 

 

22h

Main battery discharge current is over 0.5A when there is no load.

 

 

23h

Main battery charge current is over 3.9A when AC adapter is not

 

connected.

24h

Abnormal current has been sensed.

 

 

25h

Main battery charge current is over 0.3A.

 

 

‰Second Battery

Error code

Meaning

 

 

32h

Second battery discharge current is over 0.5A when there is no load.

 

 

33h

Second battery charge current is over 3.9A. when AC adapter is not

 

connected.

34h

Abnormal current has been sensed.

 

 

35h

Second battery charge current is over 0.3A.

 

 

‰S3V output (P60)

Error code

Meaning

 

 

40h

S3V voltage is 3.47V or less when the computer is powered on/off.

 

 

45h

S3V voltage is 3.14V or less when the computer is powered on.

 

 

46h

S3V voltage is 3.14V or less when the computer is booting up.(CV

 

support)

 

 

Satellite A50S/TECRA A3X Maintenance Manual (960-534)

[CONFIDENTIAL]

2-9

Page 65
Image 65
Toshiba A3X manual ‰ DC power supply AC adapter, Error code Meaning