2.3 Power Supply Troubleshooting 2 Troubleshooting Procedures
Satellite A50S/TECRA A3X Maintenance Manual (960-534) [CONFIDENTIAL] 2-9
DC power supply (AC adapter)
Error code Meaning
10h AC Adapter output voltage is over 16.5V.
11h Common Dock output voltage is over 16.5V.
12h Current from the DC power supply is over 7.00A.
13h Current from the DC power supply is over 0.5A when there is no load.
14h Abnormal current has been sensed.
Main Battery
Error code Meaning
22h Main battery discharge current is over 0.5A when there is no load.
23h Main battery charge current is over 3.9A when AC adapter is not
connected.
24h Abnormal current has been sensed.
25h Main battery charge current is over 0.3A.
Second Battery
Error code Meaning
32h Second battery discharge current is over 0.5A when there is no load.
33h Second battery charge current is over 3.9A. when AC adapter is not
connected.
34h Abnormal current has been sensed.
35h Second battery charge current is over 0.3A.
S3V output (P60)
Error code Meaning
40h S3V voltage is 3.47V or less when the computer is powered on/off.
45h S3V voltage is 3.14V or less when the computer is powered on.
46h S3V voltage is 3.14V or less when the computer is booting up.(CV
support)