4.23 Fluorescent Lamp

4 Replacement Procedures

4.23 Fluorescent Lamp

This system uses LCD modules from the following suppliers. The procedure for replacing the fluorescent lamp is different for each LCD module. Refer to the appropriate procedure.

Type

Part No.

Supplier

Section

 

 

 

 

15.0 inch

G33C0002W110

Samsung

4.23.1

(XGA)

 

 

 

G33C0002Y110

Sharp

4.23.2

 

 

 

 

 

 

G33C00030110

LG.Philips

4.23.3

 

 

 

 

15.0 inch

G33C0001X210

LG.Philips

4.23.4

(SXGA+)

 

 

 

 

 

 

 

NOTE: - When working with a LCD module, always use a flat, grounded table.

(1)Handle the backlight unit in the environment without dust, such as on the clean bench. Keep the worktable free from any screws or other material that may scratch the LCD surface.

(2)Use an anti-static or protective sheet.

(3)When replacing the FL unit, cover with a finger protector or similar to prevent dirtying or scratching the LCD panel.

(4)Take care when handling the lamp. Excessive force may break the lamp.

(5)Take care not to dirty or deform the lamp reflector.

(6)Ensure always that the power of the LCD module is turned off before connecting or disconnecting cables and connectors.