3 Tests and Diagnostics

3.30 Sound Test program

3.30.3 CD Sound (Standard) test

To execute the CD Sound (Standard) test, press 3 and Enter. Insert the test media (TOSHIBA TEST CD-ROM or ABEX TEST CD-ROM) or music CD on the market (if the test media can not be prepared). Following menu appears in the display.

For details on use of test media, refer to (1) Test media (Toshiba-made test media). For details on use of audio CD on the market, refer to (2) Audio CD.

(1)Test media (Toshiba-made test media)

CD/DVD TEST IN PROGRESS XXXXXXXX

xxxxxxxDIAGNOSTIC TEST VX.XX [Ctrl]+[Break] ; test end

[Ctrl]+[C]

; key stop

SUB-TEST

: XX

ERROR COUNT: XXXXX

PASS

COUNT : XXXXX

WRITE DATA

: XX

READ DATA

: XX

ADDRESS

: XXXXXX

STATUS

: XXX

01

Japanese Narration

 

02

English Narration

 

 

03

Test Tone A (100Hz – 20Hz)

 

04

-

Test Tone B (400Hz – 3KHz L-R)

Drive # = 0, ATAPI status =00 Command = XX

[[Block address = XXXXXXXX]] [[Block length = XXXXXXXX]]

Final : Block address = XXXXXXXXX

Subtest01

Japanese Narration

 

Selected this subtest, narration in Japanese starts and following message

 

appears in the display.

 

Play start CD sound !

 

Press any key <Play stop>.

 

Press any key and stop the narration. Then return to the CD Sound (Standard)

 

test menu.

Satellite A50S/TECRA A3X Maintenance Manual (960-534)

[CONFIDENTIAL] 3-87

Page 197
Image 197
Toshiba A3X manual CD Sound Standard test, Pass Count Write Data Read Data Address Xxxxxx Status XXX