4 Replacement Procedures 4.20 LCD Unit/FL Inverter
4-60 [CONFIDENTIAL] Satellite A50S/TECRA A3X Maintenance Manual (960-534)
Installing the FL inverter/LCD unit
The following describes the procedure for installing the LCD unit/FL inverter (See Figure 4-
40 to 4-42).
1. Secure the LCD brackets to the LCD module with the following screws.
M2x3C SUPER THIN BIND screw x4
2. Stand the LCD unit on the display cover and connect the LCD harness to the back of
the LCD. Fix it with the cupper tape.
3. Put the LCD unit on the display cover and secure the LCD with the following screws.
M2x4Z SUPER THIN BIND screw x4
4. Connect LCD harness and HV cable to the connectors on the FL inverter.
5. Secure the FL inverter with the following screw.
M2x4Z SUPER THIN BIND screw x1
6. Stick the insulators on the HV cable side and tuck the insulator1 under LCD unit.
7. Install the display mask and engage the latches.
NOTE: When installing the display mask, make sure there is no gap between the display
mask and the display cover.
8. Secure the display mask with the following screws and stick two mask seals on the
front of the display mask.
M2.5x6B THIN BIND screw x2