SPX Cooling Technologies FSIG-TS-08A specifications Specifications, Specification Value, 1.0Base

Models: FSIG-TS-08A

1 30
Download 30 pages 19.14 Kb
Page 12
Image 12
Specifications

Marley / Sigma F Series CoolingTower / Specifications: Base

12

 

 

Specifications

 

Specification Value

1.0Base:

1.1

Furnish and install an induced-draft,

Your specification base establishes the type, configuration, base

 

crossflow-type, field-erected, structural

material, and physical limitations of the cooling tower to be

 

fiberglass-framed, PVC film-fill, industrial-

quoted. During the planning and layout stages of your project,

 

duty cooling tower of _____ cell(s), as

you will have focused your attention on a cooling tower selection

 

shown on Plans. The limiting overall

that fits your space allotment, and whose power usage is accept-

 

dimensions of the tower shall be _____

able. Limitations on physical size and total operating horsepower

 

wide, _____ long, and _____ high to the

avoid the introduction of unforeseen operational and site-related

 

top of the fan cylinder. Total operating

influences. Specifying the number of cells, and the maximum fan

 

horsepower of all fans shall not exceed

hp/cell will work to your advantage.

 

____ hp, driven by ___ @ _____ hp

Your reason for specifying a crossflow type is that crossflow tow-

 

motor(s). Pump head, including static lift

 

above top of cold water basin curb (or

ers are noted for the accessibility and maintainability of all oper-

 

top of supporting steel), shall not exceed

ating components. The spacious interior provides easy access

 

____ feet of water. Tower shall be simi-

to fill, drift eliminators, all basin accessories—and is one of two

 

lar and equal in all respects to Marley

primary accessways to the fan, Geareducer, and other mechani-

 

Sigma F Series, Model _______.

cal components.

 

 

At the fan deck level, the hot water distribution basins are easily

 

 

inspected and cleaned—while the tower is operating, if neces-

 

 

sary. The mechanical equipment can also be readily accessed

 

 

from this level.

 

 

Except for the cold water basin, no counterflow tower component

 

 

requiring routine maintenance is as easily accessed. The confined

 

 

areas that typify counterflow designs, particularly of forced draft

 

 

configuration can make difficult work for maintenance personnel!