DIGITAL VIDEO RECORDER

GB

 

 

GB

 

4

3

 

 

System Connection for Alarm Recording

Connection with PC for Use

<Rear Side Connection Terminal of SHR-3010>

<Outside Product>

1

2

3

4

5

6

7

8

9

10

11

1

2

3

4

5

1

ALARM IN

1

GND

2

ALARM RESET

2

TRIGGER IN

3

ALARM OUT

3

ALARM IN

6

TRIGGER OUT

4

ALARM CANCEL

1

GND

5

ALARM OUT

Alarm recording is a function for recording the input video when an alarm signal is input while a device with alarm output is connected to this unit.

Connect to the corresponding terminals, as the numbers may be different for external devices.

For external devices, if the alarm input (ALARM INPUT) and alarm cancel (ALARM CANCEL) are not available, you can leave them unconnected.

Connection with RS-232C

A. Communication Method

Data Code: ASCII Code

Protocol: 8 bit Data, 1 Stop bit, None Parity

Transmission speed: 4800, 9600, 19200, 38400 bps

B. RS-232C terminal (D-SUB 9 Pin) and Pin specifications

5

1

96

Pin No

Pin Specifications

 

 

2

TXD (Transmitted Data)

 

 

3

RXD (Received Data)

 

 

5

SG (Signal Ground)

 

 

1, 4, 6~9

NO Connection

 

 

2-3

2-4