➼ CTRL TYPE
This function is not used on the Anti-Vandal Dome Camera.
➼ RS485
Select the Baud Rate (4800, 9600, 19200, or 38400 bps) and Camera Address (0~255) for RS485 communication. When using a multiple number of cameras, each must use a different address. (If the same address is used, communica- tion may not be possible.)
➼ PRESET
You can select and store the desired ZOOM and FOCUS positions from 0 to 9.
➼ D-ZOOM
Sets the magnification of the Digital Zoom. Magnification can be set between 2x and 10x in 5 step increments.
➼ PIP
Picture In Picture function. Shows a 1/16 screen only when operating the Digital Zoom. If the D-ZOOM is OFF, a ‘disbled’ symbol (—) will be displayed.
➼ MIRROR
Horizontally flips the video output signal.
➼ POSI/NEGA
Outputs the video output signal normally or inversely.
➼ ZOOM SPEED
Sets the Zoom speed. Pressing the [LEFT, RIGHT] keys in the ZOOM SPEED menu will change the zoom speed as follows:
1 : Takes about 14 seconds from 1x to x12 Slowest speed
2 : Takes about 6 seconds from 1x to x12 Slow speed
3 : Takes about 4 seconds from 1x to x12 Fast speed
4 : Takes about 2 seconds from 1x to x12 Fastest speed
➼ DETAIL
Adjusts the horizontal and vertical sharpness.
If you select ON and press the [ENTER] key, a “SPECIAL” submenu screen where you can set special functions will be displayed.
00356A SID-600P-eng 12/10/02 12:14 PM Page 34
CAMERA MENU Organization
SYNC
Select INT when using the interal synchronization. LINE... is necessary when syn- chronizing the camera phases to operate multiple cameras by using the external signal (AC signal -60Hz(NTSC), AC signal -50Hz(PAL)).
EYou can adjust the PHASE to eliminate any phase deviation between each CAM- ERA set.
| CAMERA ID | OFF... | | | (LINE LOCK) |
| IRIS | ALC... | | | | |
| AUTO FOCUS | AF | | | | |
| SHUTTER | AUTO X8 | | | | |
| MOTION | F.FAST | | | | |
| WHITE BAL | ATW | When you press | | |
| SYNC | | LINE... | | |
| | the [ENTER] key | | |
| SPECIAL | ... | PHASE | (000) -------- |
| | |
| MOTION DET | OFF | | | RET |
| EXIT | QUIT | | | | |
You can use this function when using the AC power.
With the DC voltage, you will not be able to set the SYNC with —-.
Position the cursor on the SYNC and use the [LEFT/RIGHT] keys to select the desired sychronization from INT/LINE... When you select LINE... and press the [ENTER] key, a submenu screen where you can adjust the PHASE will appear.
You can adjust the PHASE for NTSC from -106 to +106, and for PAL from -138 to +138.
SPECIAL
In the SPECIAL menu, you can directly control the POSI/NEGA, PIP, MIRROR, horizontal sharpness, and vertical sharpness.
34