Functional Description

6) Initialization Setting

Initialization Menu

Main Menu

Initialize

Camera Setting

Power ON Reset

Sequence Setting

Factory Default Set

P/T Setting

Camera Default Set

OSD Setting

Auto Refresh OFF

Alarm Setting

 

Initialize

 

Status

 

Power On Reset

: Camera is initialized into the original status of power

 

input.

Factory Default Settings : Camera is initialized into the factory default settings. Data including Preset is deleted. This function is used for initialization all settings.

Camera Default Settings: If only the camera module is replaced due to camera module failure, the new camera module can be set up with the settings of the old camera module.

Auto Refresh : The electric circuit and the status of the equipment parts within the camera are optimized regularly. (The cycle can be set up.) If camera faces toward a certain source of light or if the settings cannot be kept because of the long time rotation filming of a certain area, the Auto Refresh function is used to maintain and re-set the existing camera settings. Default setting is OFF.

OFF, 1-7 Days : This function is disabled in the OFF mode. 1-7 Days enables the Auto Refresh operation in the interval of the selected days. Auto Refresh takes less than 10 seconds. The message “Auto Refresh” disappears after finishing the operation.

7) Status

The status of dome camera setting is displayed.

Main Menu

Camera Status

Camera Setting

CAM MODER

= 30NC

Sequence Setting

CAM VERSION

= 03.06

P/T Setting

DOME VERSION

= 00.18

OSD Setting

CON PROTOCOL

= SAMSUNG TW

Alarm Setting

DOME ID

= 001

Initialize

CONTROLLER

= Duplex-9600

Status

 

 

Cam Model = 30NC

Camera Model

Cam Version = 03.06

Camera S/W Version

Dome Version = 00.01

Control Board S/W Version

Dome ID=001

Dome Camera ID

Controller=Duplex-9600

Communication Mode Setup

ENGLISH

SPEED DOME CAMERA 58 User’s Manual

SPEED DOME CAMERA 59 User’s Manual

Page 30
Image 30