8. INSTALLATION INSTRUCTIONS
2)Selecting the Installation Site
Indoor Unit
AVOID:
ãareas where leakage of flammable gas may be expected.
ãplaces where large amounts of oil mist exist.
ãdirect sunlight.
ãlocations near heat sources which may affect performance of the unit.
ãlocations where external air may enter the room directly. This may cause “sweating” on the air discharge ports, causing them to spray or drip.
ãlocations where the remote control unit will be splashed with water or affected by dampness or humidity.
ãinstalling the remote control unit behind curtains or furniture.
ãlocations where the receiver in the indoor unit is exposed to the inverter lamp light. Faulty operation of the unit occurs.
DO:
ãselect an appropriate position from which every corner of the room can be uniformly cooled.
ãselect a location where the ceiling is strong enough to support the weight of the unit.
ãselect a location where tubing and drain pipe have the shortest run to the outdoor unit.
ãallow room for operation and maintenance as well as unrestricted air flow around the unit.
ãinstall the unit within the maximum elevation difference above or below the outdoor unit and within a total tubing length from the outdoor unit as detailed in Table 1.
ãallow room for mounting the remote control unit about 3 ft. off the floor, in an area that is not in direct sunlight nor in the flow of cool air from the indoor unit.
NOTE
Air delivery will be degraded if the distance from the floor to the ceiling is greater than 10 ft..
Ceiling-Mounted Type
| Ceiling |
| Wall |
Min.10 inch | Min.10 inch |
Front view
NOTE
The rear of the indoor unit can be installed flush against the wall.
AirCeiling discharge
|
|
| Air intake |
Min.2ft. |
| ||
|
| ||
|
|
|
|
Side view
1379_T_I
Recessed Type
3 ft. | 3 ft. |
| |
| 3 ft. |
3 ft.
3 ft.
1330_X_S
SM830078
– 34 –