8. INSTALLATION INSTRUCTIONS

3)Electrical Wiring

General Precautions on Wiring

(1)Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram.

(2)Provide a power outlet to be used exclu- sively for each unit, and a power supply disconnect and circuit breaker for overcurrent protection should be pro- vided in the exclusive line.

(3)To prevent possible hazards from insula- tion failure, the unit must be grounded.

(4)Each wiring connection must be done in accordance with the wiring system dia- gram. Wrong wiring may cause the unit to misoperate or become damaged.

(5)Do not allow wiring to touch the refriger- ant tubing, compressor, or any moving parts of the fan.

(6)Unauthorized changes in the internal wiring can be very dangerous. The manu- facturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes.

(7) Regulations on wire diameters differ from locality to locality. For field wiring rules, please refer to your LOCAL ELECTRI- CAL CODES before beginning. You must ensure that installation complies with all relevant rules and regulations.

(8) To prevent malfunction of the air condi- tioner caused by electrical noise, care must be taken when wiring as follows:

ã The inter-unit control wiring and the remote control wiring (option) should be wired apart from the inter-unit power wiring.

ã It is recommended that shielding wires or twisted pair wires be used for the remote control and the inter-unit control wiring if the air conditioner is installed where it is exposed to the influence of electrical and/ or electro-magnetic noise.

Recommended Wire Length and Wire Diameter for Power Supply System

 

(A)*1 Power Supply

(B)*1 Inter-unit

Time Delay

Power Supply Terminal Base

Models

 

Wiring

Fuse or

(Outdoor Unit)

 

 

Circuit

Capacity

 

Max. Wire

 

 

 

 

 

 

AGW #14

Capacity

 

Diameter

 

 

 

 

C4232, CL4232

65 ft. (AGW #10)

164 ft.

50 A

50 A

 

AWG #6

 

 

 

 

 

 

 

*1 Refer to the Wiring System Diagrams (See below diagram) for the meaning of “A”, “B”.

AWG = American Wire Gauge

NOTE

To access the electrical component box, open the air intake grille and remove the electrical component box cover.

Wiring System Diagram

Outdoor Unit : “C”, “CL” models Single-phase

60 Hz, 208 / 230 V

Disconnect sw (Field supply)

Indoor

Unit

Outdoor

Unit

 

 

(B)

 

1

 

1

 

2

 

2

 

G

Ground

G

 

 

 

 

4

 

4

(A)

 

 

 

 

 

L1

 

 

 

L2

 

 

 

G

 

Ground

1368_M_I

SM830078

– 37 –

Page 37
Image 37
Sanyo CL4232, C4232 service manual Electrical Wiring General Precautions on Wiring, Wiring System Diagram

CL4232, C4232 specifications

The Sanyo C4232 and CL4232 are renowned models in the realm of electronics, particularly celebrated within the realm of consumer appliances and consumer electronics. As part of Sanyo’s esteemed lineup, these models are crafted with both functionality and performance in mind, appealing to a wide demographic of users.

One of the standout features of the Sanyo C4232 and CL4232 is their energy efficiency. Both models leverage advanced technology to minimize power consumption, making them environmentally friendly options. This is particularly beneficial in today’s world, where sustainable practices are becoming increasingly vital. Users can enjoy the performance of these devices without the guilt of excessive energy expenditure.

In terms of design, the Sanyo C4232 and CL4232 showcase a sleek and modern aesthetic, incorporating user-friendly interfaces that simplify operation. The control panels are intuitively designed, allowing users to navigate options effortlessly. This focus on user experience is evident in the thoughtfulness of the layout and accessibility of controls, making these models suitable for consumers of all ages.

The Sanyo C4232 and CL4232 are also equipped with a variety of advanced features that enhance their usability. For instance, many models come with multiple settings that cater to different user needs, whether it be cooking, cooling, or heating. This versatility ensures that the units can effectively meet diverse requirements, making them indispensable in any household.

Another key characteristic of these models is their durability. Sanyo products are known for their robust construction and long-lasting performance. By utilizing high-quality materials and rigorous testing processes, Sanyo ensures that both the C4232 and CL4232 can withstand the rigors of daily use, providing consumers with reliable service over time.

Modern technology is integrated throughout the Sanyo C4232 and CL4232 models, including smart functionalities that align with contemporary lifestyles. Many of these appliances can be connected to home networks, allowing for remote control and monitoring via mobile devices. This connectivity not only enhances convenience but also allows users to manage their energy consumption efficiently.

In summary, the Sanyo C4232 and CL4232 offer a blend of efficiency, user-friendly design, durability, and modern technology. These models exemplify Sanyo’s commitment to providing practical and reliable solutions for consumers, making them worthy investments for any household looking to enhance their quality of life through innovative electronics.