Sanyo CL4232, C4232 service manual Low ambient control

Models: CL4232 C4232

1 66
Download 66 pages 250 b
Page 9
Image 9

2.SPECIFICATIONS

(1)Unit Specifications

 

MODEL No.

 

Indoor Unit

 

 

TS4232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Unit

 

 

CL4232

 

 

 

POWER SOURCE

 

 

 

 

230 - 208 V / 1 Phase / 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

PERFORMANCE

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

BTU / h

42,000

 

40,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW

12.32

 

 

11.88

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (Hi)

 

cu.ft. / min.

900

 

 

800

 

 

 

 

 

 

 

 

 

 

 

 

Moisture removal (High)

 

Pints / h

14.8

 

 

14.6

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRICAL RATINGS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage rating

 

 

VAC

230

 

 

208

 

 

 

 

 

 

 

 

 

 

 

 

 

Available voltage range

 

 

VAC

 

187 - 253

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Running amperes*

 

 

A

20.6

 

 

21.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. running amperes**

 

 

A

21.4

 

 

22.7

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input

 

 

W

4,190

 

 

4,100

 

 

 

 

 

 

 

 

 

 

 

 

 

Power factor

 

 

%

88

 

 

94

 

 

 

 

 

 

 

 

 

 

 

 

S.E.E.R

 

BTU / Wh

10.2

 

 

10.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. starting amperes

 

 

A

134

 

 

134

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum fuse size

 

 

A

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Controls

 

 

 

 

Microprocessor

 

 

 

 

 

 

 

 

 

 

 

 

 

Low ambient control

 

 

 

 

Built-in 0 °F

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

ON / OFF 24-hours & Program

 

 

 

 

 

 

 

 

 

 

 

Fan speed Indoor / Outdoor

 

 

 

3 and Automatic control / 3 (Auto)

 

 

 

 

 

 

 

 

 

 

 

Air deflection

Horizontal / Vertical

 

Manual / Automatic

 

 

 

 

 

 

 

 

 

 

 

Air filter

 

 

 

Washable, easy access, long life (2,500 hr)

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote controller (Accessory)

 

 

 

 

RCS - 5PS4U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant control

 

 

 

 

Capillary tube

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant tubing connections

 

 

 

 

Flare type

 

 

 

 

 

 

 

 

 

 

 

 

 

Drain pipe trade size

 

 

 

 

3 / 4 in. (26.7 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor

 

 

 

 

Scroll

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation sound

 

Indoor - Hi / Me / Lo

 

dB - A

 

42 / 40 / 35

 

 

 

 

 

Outdoor - Hi

 

dB - A

 

56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT TUBING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of tubing length

 

ft.

(m)

 

165 (50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit of tubing length at shipment

 

ft.

(m)

 

50 (15)

 

 

 

 

 

 

 

 

 

 

 

Limit of elevation difference

 

ft.

(m)

Outdoor unit is higher than indoor unit: 165 (50)

 

between the two units

 

 

 

Outdoor unit is lower than indoor unit: 100 (30)

 

 

 

 

 

 

 

 

 

 

 

Refrigerant tube

 

Narrow tube

in. (mm)

 

3 / 8 (9.52)

 

 

 

outer diameter

 

Wide tube

in. (mm)

 

3 / 4 (19.05)

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant amount at shipment

 

lbs. (kg)

 

R22 : 9.7 (4.4)

 

 

 

 

 

 

 

 

 

 

 

 

DIMENSIONS & WEIGHT

 

 

 

Indoor unit

 

Outdoor unit

 

 

 

 

 

 

 

 

 

 

 

Unit dimensions

 

Height

in. (mm)

9-7/16

(240)

 

48-5/8

(1,235)

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

62

(1,575)

 

37

(940)

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

26-3/8

(670)

 

13-3/8

(340)

 

 

 

 

 

 

 

 

 

 

 

Package dimensions

 

Height

in. (mm)

12-15/32

(317)

 

52-7/32

(1,326)

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

in. (mm)

66-1/16

(1,678)

 

40

(1,016)

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

in. (mm)

31-1/16

(789)

 

16-3/8

(416)

 

 

 

 

 

 

 

 

 

 

 

Net weight

 

lbs. (kg)

84

(38)

 

205

(93)

 

 

 

 

 

 

 

 

 

 

 

Shipping weight

 

lbs. (kg)

97

(44)

 

229

(104)

 

 

 

 

 

 

 

 

 

 

 

Shipping volume

 

cu.ft. (m3)

14.8

(0.42)

 

19.8

(0.56)

Cooling :

 

DATA SUBJECT TO CHANGE WITHOUT NOTICE

: Indoor air temperature 80 °F DB / 67

°F WB, Outdoor air temperature 95 °F DB / 75 °F WB

Rating conditions (*)

Full load conditions (**)

: Indoor air temperature 80 °F DB / 67

°F WB, Outdoor air temperature 115 °F DB

 

 

SM830078

– 9 –

Page 9
Image 9