![](/images/new-backgrounds/1007564/7564129x1.webp)
12. SERVICE PROCEDURES
6Continuity of fuse on P.C.B. Ass’y
•Check for continuity using a multimeter as shown in Fig. 19.
NOTE
Method Used to Replace Fuse on PCB Ass’y
1.Remove the PCB Ass’y from the electri- cal component box.
2.Remove the fuse from PCB Ass’y using pliers while heating the soldered leads on the back side of the PCB Ass’y with a soldering iron (30W or 60W). (Fig. 20)
3.For replacement, insert a fuse of the same rating to the intended position and solder it.
(Allow time to radiate heat during sol- dering so that the fuse does not melt.)
When replacing the CAUTION fuse, be sure not to
break down the varis- tor.
4)Thermistor Characteristic Curve
Fuse
1042_X_S
Fig. 19
Soldering iron
PCB Ass’y
Fuse Varistor
Pliers
1043_X_S
Fig. 20
1Room temp. sensor (KTEC-35)
| 10 | ||
| 9 | ||
) | 8 | ||
(kn | |||
| 7 | ||
Resistance |
| ||
| |||
| 6 | ||
|
| ||
|
| 5 | |
|
| ||
| 4 |
3
2
1
50 59 68 77 86 95 104
Temperature (°F)
1044_M_I
Resistance (kn )
1Coil sensor (PBC-41E)
40
35
30
25
20
15
10
5
0
5 | 14 | 23 | 32 | 41 | 50 | 59 | 68 |
Temperature (°F) 1045_M_I
SM830078
– 65 –